Anti-His Magnetic Beads |
Catalog No.GK30007 |
Anti His Magnetic Beads were used for immunoprecipitation (IP) experiments on bacterial and mammalian cell lysates as well as His tag proteins in vitro expression systems.
Products are for research use only. Not for human use. We do not sell to patients.
Sample solution is provided at 25 µL, 10mM.
Anti-His Magnetic Beads are used for immunoprecipitation (IP) of specific His-tagged proteins expressed in bacterial and mammalian cells and in vitro expression systems. Anti-His magnetic beads are based on carboxyl magnetic beads, with 2 μm particle size, covalently coupling with high quality mouse IgG monoclonal antibody that recognizes the His tag. Magnetic beads are removed from the solution manually by using a magnetic stand or automatically by using an instrument. With high loading of His-tagged protein and high specificity, Anti-His Magnetic Beads are also suitable for Co-immunoprecipitation and purification of His-tagged protein.
Storage:Stored at 4°C, and is stable for up to 2 years.
Do not centrifuge, dry or freeze the magnetic beads.
1. Preparation of Magnetic Beads
1.1 Resuspend the Magnetic Beads in the vial (tilt and rotate for 2 minutes or gently pipette for 10 times, do not vortex). Transfer 25 μL of Anti-c-Myc Magnetic Beads suspension into a new tube.
1.2 Add 500 μL of wash buffer to the beads and gently pipette to mix. Place the tube into a magnetic stand (MCE Cat. No.: HY-K0200) to collect the beads against the side of the tube. Remove and discard the supernatant. Repeat this step for 2 times
2. Protein Binding
2.1 Add 500 μL of cell lysate (the sample containing c-Myc-tagged protein) to the washed beads. For Ag binding, incubate for 2 hours at room temperature or overnight at 4°C while gently rotating the tube.
2.2 Place the tube into a magnetic stand to collect the beads against the side of the tube. Remove and discard the supernatant.
NOTE: Occasional aggregation of magnetic beads during the binding process doesn’t affect experimental results.
3. Washing
Add 500 μL of wash buffer to the Magbeads-Ag complex and mix gently. Place the tube into a magnetic stand to collect the beads against the side of the tube. Remove and discard the supernatant. Repeat this step for 3 times.
4. Elution & Detection
Three elution methods are recommended according to protein characteristics or further usage:
1) Elution with sample buffer for gel electrophoresis and immuoblotting. Add 100 μL of 1× SDS-PAGE loading buffer to each tube and boil for 5 minutes. Cool and place the tube into a magnetic stand to collect the beads and transfer the supernatant to a new tube. Keep the supernatant containing the target antigen for SDS-PAGE analysis
2) Elution with Elution Buffer A under acidic condition. Add 100 μL of Elution Buffer A to each tube. Incubate with gentle shaking or on a rotator for 10 minutes at room temperature. Place the tube into a magnetic stand to collect the beads and transfer the supernatant to a new tube. Adding 10-20 μL of Neutralization Buffer for each 100 μL of eluate to neutralize the low pH, which may help preserve bioactivity of target protein.
3) Elution with Elution Buffer B under native condition. Add 3-5 (v/v) volume of Elution Buffer B to each tube. Incubate with gentle shaking or on a rotator for 1 hour at room temperature or 2 hours at 4°C. Place the tube into a magnetic stand to collect the beads and transfer the supernatant to a new tube. For immediate use, store the eluates at 4°C, or store at -20°C for long term storage.
Applications |
Composition: Mouse IgG monoclonal antibody covalently coupled to a blocked magnetic bead surface
Bead Diameter: 200 nm Binding Capacity: > 0.5 mg protein/mL of beads Application: IP, Co-IP, Protein Purification Recommended Dose: 25 μL for per 500 μL cell lysates |
Shipping | Ship with blue ice. |
Storage Conditions | 4°C, 2 years. Do not centrifuge, dry or freeze the magnetic beads. |
Usage | For research use only! Not for use on humans. |
Average Rating: 5
(Based on Reviews and 30 reference(s) in Google Scholar.)GLPBIO products are for RESEARCH USE ONLY. Please make sure your review or question is research based.
Required fields are marked with *