GLPBio

Hoechst 33342 analog 2 trihydrochloride

Catalog No.: GC36246Purity:>98.00%
Hoechst 33342 analog 2 trihydrochloride は、Hoechst 33342 のアンログです。

製品は研究用途にのみ使用できます。人体には使用できません。患者への販売は行っておりません。


Hoechst 33342 analog 2 trihydrochloride
Cas No.: 155815-98-8
10mM (in 1mL Water)In Stock
$471.00
1
5mgIn Stock
$324.00
1
50mgIn Stock
$1,391.00
1

引用文献 (Citations)

現在、この製品の引用文献はありません。以下はGlpBio製品を引用した代表的な文献です。
  • Nature cover
    Nature
    641, 529–536 (2025)
  • Nature cover
    Nature
    628, 630–638 (2024)
  • Nature cover
    Nature
    632, 686–694 (2024)
  • Nature cover
    Nature
    618, 1017–1023 (2023)
  • Nature cover
    Nature
    610, 366–372 (2022)
  • Cell cover
    Cell
    187(9):2288-2304 (2024)
  • Cell cover
    Cell
    183(7):1867-1883 (2020)
  • Science cover
    Science
    388(6745) (2025)
  • Science cover
    Science
    387(6739) (2025)
  • Science cover
    Science
    387(6734) (2025)
  • Cell Research cover
    Cell Research
    35, 97–116 (2025)
  • Cell Research cover
    Cell Research
    34, 683–706 (2024)
  • Cell Research cover
    Cell Research
    33, 273–287 (2023)
  • Cell Research cover
    Cell Research
    33, 546–561 (2023)
  • Cell Research cover
    Cell Research
    33, 904–922 (2023)
  • Cell Research cover
    Cell Research
    31, 1291–1307 (2021)

製品説明 (Description)

Hoechst 33342 analog 2 trihydrochloride is an analog of Hoechst 33342 dye. Hoechst 33342 is a nuclear dye that binds to the grooves in the DNA double strands. Hoechst 33342 dye is also used to differentiate between normal cells, apoptotic cells, and necrotic cells. The nuclei of normal cells are round and uniformly stained, but during mitosis, the nuclei are also condensed, and DNA forms two parallel lines when chromosomes are separated; in apoptotic cells, due to the condensation of DNA, the nuclei are usually fragmented and stained more Strong; the DNA in necrotic cells is not concentrated, and the edges of the nucleus are unclear[1].

Hoechst dyes can also be used to monitor cell viability by tracking changes in their emission spectra. As slightly groove-binding DNA stains with AT selectivity, Hoechst dyes are able to bind to all nucleic acids, but they show greater fluorescence enhancement for AT-rich double-stranded DNA strands compared to GC-rich strands[2]. This property has been used to identify Q bands in chromosomes, which are AT base pair-rich regions that fluoresce brightly when stained with quinacrine dye[3].
References:
[1]. Lisa C Crowley, Brooke J Marfell , Nigel J Waterhouse. Analyzing Cell Death by Nuclear Staining with Hoechst 33342. 2016 Sep 1;2016(9). doi: 10.1101/pdb.prot087205.
[2]. Portugal J, Waring MJ. Assignment of DNA binding sites for 4′, 6-diamidine-2-phenylindole and bisbenzimide (Hoechst 33258). A comparative footprinting study. Biochimica et Biophysica Acta (BBA)-Gene Structure and Expression. 1988 Feb 28;949(2):158-68.
[3]. Weisblum B, Haenssler E. Fluorometric properties of the bibenzimidazole derivative Hoechst 33258, a fluorescent probe specific for AT concentration in chromosomal DNA. Chromosoma. 1974 Sep;46(3):255-60.

実験プロトコル (Protocol)

This plan only provides a guide, please modify it to meet your specific needs.
1. Prepare Hoechst staining solution
(1) Prepare Hoechst dye stock solution: Use DMSO to dissolve solid and prepare a 10 mg/mL Hoechst dye stock solution.
Note: Hoechst stock solution is recommended to be aliquoted and stored in the dark at -4°C or -20°C to avoid repeated freezing and thawing.
(2) Working solution preparation: Use preheated serum-free medium or buffer (such as HBSS or PBS) to dilute the stock solution and prepare a Hoechst working solution with a concentration of 10 μg/mL.
Note: Please adjust the concentration of Hoechst working fluid according to the actual situation and prepare it immediately.
2. Cell staining
2.1 Suspension cells (taking 6-well plate as an example)
(1) Centrifuge suspended cells at 1000g for 3-5 minutes. Discard the supernatant and wash twice with PBS for 5 minutes each time.
(2) Add 1 mL of Hoechst 33342 dye working solution and incubate at room temperature in the dark for 5-10 minutes.
(3) After the incubation, centrifuge at 1000g for 5 minutes, remove the supernatant, add PBS and wash 2-3 times, 5 minutes each time.
(4) Use serum-free cell culture medium or PBS to resuspend the cells and observe them through fluorescence microscopy or flow cytometry.
2.2 Adherent cells
(1) Culture adherent cells on sterile coverslips.
(2) Remove the coverslip from the culture medium, suck out the excess culture medium, and place the coverslip in a humid environment.
(3) Add 100uL of Hoechst dye working solution from one corner of the coverslip, shake gently to evenly cover all cells with the dye, and incubate at room temperature in the dark for 5-15 minutes.
(4) Aspirate away the dye working solution, wash the coverslip 2 to 3 times with culture solution, and observe with a fluorescence microscope.
3. Microscope detection: The excitation/emission light of Hoechst 33342 is 350/461nm respectively.

Precautions:
① For staining of fixed cells or tissue samples, the fixative needs to be removed by rinsing after fixation;
② Hoechst 33342 staining is usually performed after other staining. If no other staining is required, Hoechst 33342 staining is performed directly;
③ To slow down fluorescence quenching, it is recommended to use anti-fluorescence quenching mounting agent;
④ Fluorescent dyes all have quenching problems, so please try to avoid light;
⑤ Hoechst 33342 is irritating to the human body. For your safety and health, please wear a lab coat and disposable gloves when operating.
References:
[1]. Lisa C Crowley, Brooke J Marfell , Nigel J Waterhouse. Analyzing Cell Death by Nuclear Staining with Hoechst 33342. 2016 Sep 1;2016(9). doi: 10.1101/pdb.prot087205.

製品資料 (Product Documents)

Purity:>98.00%Appearance:A solid

化学的性質 (Chemical Properties)

CAS番号
155815-98-8
SMILES
OC1=CC=C(C2=NC3=CC(C4=NC5=CC(N6CCN(C)CC6)=CC=C5N4)=CC=C3N2)C=C1I.[H]Cl.[H]Cl.[H]Cl
分子式
C25H26Cl3IN6O
分子量
659.78
溶解性
Water: 15.83 mg/mL (23.99 mM and warming)
保存条件
Store at -20°C
一般的な注意事項
製品の溶解性データに基づいて適切な溶媒を選択してください。調製後は、凍結融解の繰り返しを避けるため、ストック溶液を小分けしてください。
ストック溶液は、-80°Cで保存する場合は6か月以内、-20°Cで保存する場合は1か月以内に使用してください。
溶解性を高めるには、チューブを37°Cに温め、適切な時間超音波処理してください。
配送条件
評価用サンプルは保冷剤とともに発送します。その他の容量は室温で発送し、ご要望に応じて保冷剤を同梱します。

計算ツール (Calculators)モル濃度 / 希釈 / 分子量 / 単位変換 / in vivo製剤 / 溶解度

g/mol

Reviews

Review for Hoechst 33342 analog 2 trihydrochloride

Rating: 5
  • 5 Star100%
  • 4 Star0%
  • 3 Star0%
  • 2 Star0%
  • 1 Star0%