GLPBio

GP531

Catalog No.: GC32675Purity:>98.50%
GP531 ist ein potenter Adenosin-regulierender Wirkstoff der zweiten Generation, der unter Grundbedingungen pharmakologisch stumm ist, aber wÄhrend einer IschÄmie lokalisiertes endogenes Adenosin erhÖht.

Die Produkte sind ausschließlich für Forschungszwecke bestimmt. Nicht zur Anwendung am Menschen. Wir verkaufen nicht an Patienten.


GP531
Cas No.: 142344-87-4
10mM (in 1mL DMSO)In Stock
$230.00
1
1mgIn Stock
$95.00
1
5mgIn Stock
$209.00
1
10mgIn Stock
$336.00
1

Zitate (Citations)

Für dieses Produkt sind derzeit keine Zitate verfügbar. Nachfolgend finden Sie ausgewählte Publikationen, die GlpBio-Produkte zitieren.
  • Nature cover
    Nature
    641, 529–536 (2025)
  • Nature cover
    Nature
    628, 630–638 (2024)
  • Nature cover
    Nature
    632, 686–694 (2024)
  • Nature cover
    Nature
    618, 1017–1023 (2023)
  • Nature cover
    Nature
    610, 366–372 (2022)
  • Cell cover
    Cell
    187(9):2288-2304 (2024)
  • Cell cover
    Cell
    183(7):1867-1883 (2020)
  • Science cover
    Science
    388(6745) (2025)
  • Science cover
    Science
    387(6739) (2025)
  • Science cover
    Science
    387(6734) (2025)
  • Cell Research cover
    Cell Research
    35, 97–116 (2025)
  • Cell Research cover
    Cell Research
    34, 683–706 (2024)
  • Cell Research cover
    Cell Research
    33, 273–287 (2023)
  • Cell Research cover
    Cell Research
    33, 546–561 (2023)
  • Cell Research cover
    Cell Research
    33, 904–922 (2023)
  • Cell Research cover
    Cell Research
    31, 1291–1307 (2021)

Beschreibung (Description)

GP531 is a potent, second-generation adenosine regulating agent, is pharmacologically silent under basal conditions but increases localized endogenous adenosine during ischemia.

Low-dose GP531 reduces infarct size by 34% compared with vehicle and reduces the extent of the anatomic no-reflow zone by 31% compared with vehicle. Infarct size and zone of no-reflow in the high dose are reduced by 22% and 16%, respectively. GP531 does not affect hemodynamics or blood flow. GP531 is effective at the lower dose in reducing the severity of ischemic/reperfusion injury, without inducing the adverse hemodynamic effects associated with adenosine administration such as bradycardia and hypotension[1]. GP531 infusion has no effect on heart rate or mean aortic pressure but significantly decreases left ventricular end-diastolic pressure, end-diastolic volume, end-systolic volume and end-diastolic wall stress. GP531 significantly increases left ventricular EF, deceleration time of early mitral inflow velocity and the slope of end-systolic PVR without increasing MVO2[2].

[1]. Hale SL, et al. Cardioprotection with adenosine-regulating agent, GP531: effects on no-reflow, infarct size, and blood flow following ischemia/ reperfusion in the rabbit. J Cardiovasc Pharmacol Ther. 2010 Mar;15(1):60-7. [2]. Wang M, et al. Acute intravenous infusion of an adenosine regulating agent improves left ventricular function in dogs with advanced heart failure. Cardiovasc Drugs Ther. 2013 Dec;27(6):489-98.

Protokoll (Protocol)

Animal experiment:

Rabbits: Baseline hemodynamic parameters and temperature are obtained. The rabbits are randomized to 1 of 3 groups: a low dose of GP531, a high dose of GP 531, or vehicle (10% sodium metabisulfite). The low dose consists of a loading dose of 700 mg/kg given over 10 minutes starting at 12 minutes before coronary artery occlusion, followed by an infusion of 10 mg/kg per minute for the duration of the study. The high dose consists of a loading dose of 2100 mg/kg given over 10 minutes starting at 12 minutes before CAO followed by an infusion of 30 mg/kg per min for the duration of the study. All rabbits receive the same volume (12 mL over the duration of the study), so the concentrations are adjusted for body weight. The rabbits are then subjected to 30 minutes of coronary artery occlusion. The coronary artery is occluded by tightening the snare. Regional myocardial blood flow is measured during the ischemic period at 25 minutes of CAO[1]. Dog: Six dogs with intracoronary microembolizationinduced HF receive a constant intravenous infusion of GP531 (10 μg/kg/min) or vehicle (normal saline) for 6 h in random order 1 week apart. Hemodynamic measurements are made at baseline and at 1, 2, 3, 4, 5 and 6 h after initiating drug infusion. Myocardial oxygen consumption (MVO2) is measured at baseline and 4 and 6 h. LV pressure-volume relationship (PVR) is measured at baseline and 6 h[2].

References:

[1]. Hale SL, et al. Cardioprotection with adenosine-regulating agent, GP531: effects on no-reflow, infarct size, and blood flow following ischemia/ reperfusion in the rabbit. J Cardiovasc Pharmacol Ther. 2010 Mar;15(1):60-7.
[2]. Wang M, et al. Acute intravenous infusion of an adenosine regulating agent improves left ventricular function in dogs with advanced heart failure. Cardiovasc Drugs Ther. 2013 Dec;27(6):489-98.

Produktdokumente (Product Documents)

Purity:>98.50%Appearance:A solid

Chemische Eigenschaften (Chemical Properties)

CAS-Nr.
142344-87-4
SMILES
O=C(C1=C(N)N([C@H]2[C@@H]([C@@H]([C@@H](CNCC3=CC=CC=C3)O2)O)O)C=N1)N
Summenformel
C16H21N5O4
Molekulargewicht
347.37
Löslichkeit
DMSO: 125 mg/mL (359.85 mM)
Lagerung
Store at -20°C
Allgemeine Hinweise
Wählen Sie anhand der Löslichkeitsdaten des Produkts ein geeignetes Lösungsmittel. Aliquotieren Sie die Stammlösung nach der Herstellung, um wiederholte Gefrier-Auftau-Zyklen zu vermeiden.
Verwenden Sie Stammlösungen bei Lagerung bei -80°C innerhalb von 6 Monaten bzw. bei -20°C innerhalb von 1 Monat.
Zur Verbesserung der Löslichkeit das Röhrchen auf 37°C erwärmen und für eine angemessene Dauer beschallen.
Versandbedingungen
Evaluierungsmuster werden mit Kühlakkus versandt. Andere verfügbare Größen werden bei Raumtemperatur oder auf Anfrage mit Kühlakkus versandt.

Rechner (Calculators)Molarität / Verdünnung / Molekulargewicht / Einheitenumrechnung / In-vivo-Formulierung / Löslichkeit

g/mol

Reviews

Review for GP531

Rating: 5
  • 5 Star100%
  • 4 Star0%
  • 3 Star0%
  • 2 Star0%
  • 1 Star0%