GLPBio

SYP-5

Catalog No.: GC32876Purity:>99.50%
SYP-5 es un nuevo inhibidor de HIF-1 que suprime la invasiÓn de células tumorales y la angiogénesis.

Los productos son exclusivamente para uso en investigación. No aptos para uso humano. No vendemos a pacientes.


SYP-5
Cas No.: 1384268-04-5
10mM (in 1mL DMSO)In Stock
$70.00
1
5mgIn Stock
$64.00
1
10mgIn Stock
$98.00
1
50mgIn Stock
$280.00
1
100mgIn Stock
$420.00
1

Citas (Citations)

Actualmente no hay citas disponibles para este producto. A continuación se muestran publicaciones seleccionadas que citan productos GlpBio.
  • Nature cover
    Nature
    641, 529–536 (2025)
  • Nature cover
    Nature
    628, 630–638 (2024)
  • Nature cover
    Nature
    632, 686–694 (2024)
  • Nature cover
    Nature
    618, 1017–1023 (2023)
  • Nature cover
    Nature
    610, 366–372 (2022)
  • Cell cover
    Cell
    187(9):2288-2304 (2024)
  • Cell cover
    Cell
    183(7):1867-1883 (2020)
  • Science cover
    Science
    388(6745) (2025)
  • Science cover
    Science
    387(6739) (2025)
  • Science cover
    Science
    387(6734) (2025)
  • Cell Research cover
    Cell Research
    35, 97–116 (2025)
  • Cell Research cover
    Cell Research
    34, 683–706 (2024)
  • Cell Research cover
    Cell Research
    33, 273–287 (2023)
  • Cell Research cover
    Cell Research
    33, 546–561 (2023)
  • Cell Research cover
    Cell Research
    33, 904–922 (2023)
  • Cell Research cover
    Cell Research
    31, 1291–1307 (2021)

Descripción (Description)

SYP-5 is a novel HIF-1 inhibitor, suppresses tumor cells invasion and angiogenesis.

SYP-5 inhibits hypoxia-induced upregulation of HIF-1. SYP-5 inhibits HIF-1 and downstream gene expression in Hep3B and Bcap37 cells. SYP-5 inhibits tumor cell migration and invasion, as well as tumor angiogenesis, which are mediated by suppressing PI3K/AKT- and MAPK/ERK-dependent HIF-1 pathway. The proteins of vascular endothelial growth factor (VEGF) and matrix metalloproteinases (MMP)-2 that are targets of HIF-1, are down-regulated by SYP-5. SYP-5 displays significant inhibition on hypoxia-induced overexpression of VEGF and MMP2 in both cell lines. In the tube formation assay, SYP-5 suppresses angiogenesis induced by hypoxia and VEGF in vitro. SYP-5 also retards the Hep3B and Bcap37 cells migration and invasion induced by hypoxia and FBS. SYP-5 specifically inhibits hypoxic induction of luciferase expression in U251-HRE but not in U251-pGL3[1].

[1]. Wang LH, et al. SYP-5, a novel HIF-1 inhibitor, suppresses tumor cells invasion and angiogenesis. Eur J Pharmacol. 2016 Nov 15;791:560-568.

Protocolo (Protocol)

Cell experiment:

The cells (1×105 cells/mL) are seeded into 96-well culture plates. After overnight ncubation, the cells are treated with various concentrations of SYP-5 (2, 10, 50 μM) for 24 h. Then 10μLMTT) solution (2.5 mg/mL in PBS) is added to each well, and the plates are incubated for additional 4 h at 37°C. After centrifugation (2500 rpm, 10 min), the medium containing MTT is aspirated, and 100 μL DMSO is added. The optical density of each well is measured at 570 nm with a SpectraMax Paradigm Reader[1].

References:

[1]. Wang LH, et al. SYP-5, a novel HIF-1 inhibitor, suppresses tumor cells invasion and angiogenesis. Eur J Pharmacol. 2016 Nov 15;791:560-568.

Documentos del producto (Product Documents)

Purity:>99.50%Appearance:A solid

Propiedades químicas (Chemical Properties)

N.º CAS
1384268-04-5
SMILES
O=C(C1=C(O)C(C=CC(C)(C)O2)=C2C=C1)/C=C/C3=CC=CS3
Fórmula molecular
C18H16O3S
Peso molecular
312.38
Solubilidad
DMSO : 33.33 mg/mL (106.70 mM)
Almacenamiento
Store at -20°C
Consejos generales
Seleccione un disolvente adecuado según los datos de solubilidad del producto. Una vez preparada, divida la solución madre en alícuotas para evitar ciclos repetidos de congelación y descongelación.
Utilice las soluciones madre en un plazo de 6 meses si se conservan a -80°C, o de 1 mes si se conservan a -20°C.
Para mejorar la solubilidad, caliente el tubo a 37°C y soníquelo durante un periodo adecuado.
Condiciones de envío
Las muestras de evaluación se envían con acumuladores de frío. Los demás tamaños se envían a temperatura ambiente o, previa solicitud, con acumuladores de frío.

Calculadoras (Calculators)Molaridad / Dilución / Peso molecular / Conversión de unidades / Formulación in vivo / Solubilidad

g/mol

Reviews

Review for SYP-5

Rating: 5
  • 5 Star100%
  • 4 Star0%
  • 3 Star0%
  • 2 Star0%
  • 1 Star0%