CDH11-IN-1 |
|
Catalog No.GC79124
|
CDH11-IN-1 is a CDH11 inhibitor.
Products are for research use only. Not for human use. We do not sell to patients.
Cas No.: 1239467-61-8
Sample solution is provided at 25 µL, 10mM.
In Vitro, CDH11-IN-1 (Example 16) is a CDH11 inhibitor that regulates CDH11-mediated biological pathways[1].
References:
[1]. Byers, S. W., et al. Cadherin- 11 Inhibitors and Methods of Use Thereof. WO 2010/091384 A2. World Intellectual PropertyOrganization (WIPO) International Bureau. 12 August 2010. Byers. S. W. et al. Cadherin-11 Inhibitors and Methods of UseThereor. WO 2010/091384 A2 World Intellectual Property Organization (WIPO) International Bureau. 12 August 2010.
| Cas No. | 1239467-61-8 | SDF | |
| Formula | C17H13NO | M.Wt | 247.29 |
| Solubility | DMSO: ≥ 200 mg/mL (808.77 mM) | Storage | Store at -20°C |
| Shipping Condition | Evaluation sample solution: shipped with blue ice. All other sizes available: with RT, or with Blue Ice upon request. | ||
| Prepare stock solution | |||
|
1 mg | 5 mg | 10 mg |
| 1 mM | 4.0438 mL | 20.2192 mL | 40.4384 mL |
| 5 mM | 808.8 μL | 4.0438 mL | 8.0877 mL |
| 10 mM | 404.4 μL | 2.0219 mL | 4.0438 mL |
Step 1: Enter information below (Recommended: An additional animal making an allowance for loss during the experiment)
Step 2: Enter the in vivo formulation (This is only the calculator, not formulation. Please contact us first if there is no in vivo formulation at the solubility Section.)
Calculation results:
Working concentration: mg/ml;
Method for preparing DMSO master liquid: mg drug pre-dissolved in μL DMSO ( Master liquid concentration mg/mL, Please contact us first if the concentration exceeds the DMSO solubility of the batch of drug. )
Method for preparing in vivo formulation: Take μL DMSO master liquid, next addμL PEG300, mix and clarify, next addμL Tween 80, mix and clarify, next add μL saline, mix and clarify.
Method for preparing in vivo formulation: Take μL DMSO master liquid, next add μL Corn oil, mix and clarify.
Note: 1. Please make sure the liquid is clear before adding the next solvent.
2. Be sure to add the solvent(s) in order. You must ensure that the solution obtained, in the previous addition, is a clear solution before proceeding to add the next solvent. Physical methods such as vortex, ultrasound or hot water bath can be used to aid dissolving.
3. All of the above co-solvents are available for purchase on the GlpBio website.
Quality Control & SDS
- View current batch:
- Purity: >99.50% Appearance: A solid
- COA (Certificate of Analysis)
- SDS (Safety Data Sheet)
- Datasheet
Average Rating: 5 (Based on Reviews and 30 reference(s) in Google Scholar.)















